Ukugeleza komoya: 250 ~ 500m³ ukugeleza komoya
Imodeli: TEWPW C1 uchungechunge
Izici:
• Ukutholwa kwamandla okuphindwe kabili, ukusebenza kahle kokuthola ukushisa kufika ku-93%
• Ingaxhunywa emoyeni empompini yokushisa yamanzi yokupholisa pre-ukupholisa preheating okokufaka umoya omusha, ngcono induduzo
• Umoya ohlanzekile wangaphandle udlula kusihlungi sokuqala kanye nesihlungi se-H12 ohlangothini lwe-OA, ukuze kuboshwe uthuli/ PM2.5/ okunye ukungcola.
• Inzwa ye-infrared CO2 enembayo ephezulu ikhomba ngokuzenzakalelayo ukugxiliswa kwe-CO2 yasendlini futhi ilungise isivinini somoya ngobuhlakani
• Ebusika, izinga lokushisa lomoya omusha wangaphandle libonakala ngokuzenzakalelayo, futhi imojula yokushisa kagesi iqalwa ngobuhlakani
• Ukuqapha okukude kwekhwalithi yomoya wasendlini njenge-carbon dioxide, umswakama, izinga lokushisa kanye ne-PM2.5.
• Ichweba le-RS485 ligcinelwe ukulawula indawo eyodwa noma ukuxhuma kwamanye amakhaya ahlakaniphile
• Izinga lomsindo eliphansi lika-29 dB(A) (Imodi yokulala)
Imodeli | Φ D |
I-TEWPW-025(C1-1D2) | 150 |
I-TEWPW-035(C1-1D2) | 150 |
I-TEWPW-050(C1-1D2) | 200 |
Le ERV Emile ifanele iyunithi yendlu ene-headspace enganele
• Uhlelo lusebenzisa ubuchwepheshe bokubuyisela amandla emoyeni.
• Ihlanganisa ukungena komoya okulinganiselayo, ukufudumeza kuqala umoya ohlanzekile ebusika.
• Inikeza umoya ohlanzekile onempilo futhi onethezekile kuyilapho uzuza ukonga okuphezulu kwamandla, ukusebenza kahle kokuthola ukushisa kufika ku-90%.
• Gcina izindawo zamamojula omsebenzi wangokwezifiso.
• Umsebenzi wokudlula ujwayelekile.
• Ukushisisa kwe-PTC, qinisekisa ukusebenza endaweni enezinga lokushisa eliphansi ebusika
Isishintshi sokushisa se-enthalpy esiwashwayo
1.Ukushisa okuphezulu kwe-cross-counterflow enthalpy heat exchanger
2.Easy ukunakekela
Iminyaka engu-3.5-10 yokuphila
4.Kuze kufike ku-93% ukusebenza kahle kokushintshanisa ukushisa
Isici Esiyinhloko:Ukusebenza kahle kokuthola ukushisa kufika ku-85% Ukusebenza kahle kwe-Enthalpy kufika ku-76% Izinga lokushintshana komoya elisebenzayo lingaphezu kuka-98% I-selective molecular osmosis I-flame retardant, antibacterial and mildew resistance.
Umgomo wokusebenza:Amapuleti ayisicaba kanye nothayela akha amashaneli okumunca noma okukhipha umoya. amandla atholakala lapho izitimu zomoya ezimbili zidlula ku-exchanger ngokuphambana nomehluko wezinga lokushisa.
I-Villa
Isakhiwo sokuhlala
Ihhotela/Ifulethi
Isakhiwo Sohwebo
Imodeli | I-TEWPW-025(C1-1D2) | I-TEWPW-035(C1-1D2) | I-TEWPW-050(C1-1D2) |
Ukugeleza komoya (m³/h) | 250 | 350 | 500 |
Ilinganiswe nge-ESP (Pa) | 100 | 100 | 100 |
Temp.Eff. (%) | 80-93 | 75-90 | 73-88 |
Umsindo dB (A) | 34 | 36 | 42 |
Okokufaka kwamandla (W) (Umoya omusha kuphela) | 115 | 155 | 225 |
Umthamo wokupholisa ngaphambili (W) | 1200* | 1500* | 1800* |
Umthamo wokushisa wangaphambili (W) | 2000* | 2500* | 3000* |
Ukunikezwa kwamanzi (kg/h) | 210 | 270 | 320 |
I-PTC preheating (W) (Anti-freezing) | 300 (600) | ||
I-voltage elinganiselwe/imvamisa | I-AC 210-240V / 50 (60) Hz | ||
Ukuvuselelwa kwamandla | I-Enthalpy exchange core, ukusebenza kahle kokuthola ukushisa kufika ku-93% | ||
Ukusebenza kahle kokuhlanza | 99% | ||
Isilawuli | TFT Liquid crystal display / Tuya APP | ||
Imoto | Imoto ye-DC (i-Double edonsayo i-centrifugal fan yamanje) | ||
Ukuhlanzwa | Isihlungi esiyinhloko + imojuli ye-IFD(ongakukhetha)+H12 Isihlungi seHepa | ||
Imodi yokusebenza | Ukuhlanzwa komoya omusha + Umsebenzi we-By-pass | ||
Izinga lokushisa le-ambient elisebenzayo (℃) | - 25 - 40 | ||
Usayizi womkhiqizo (L*W*H)mm | 850x400x750 | ||
Isihlungi sokuvala inzalo se-IFD | Ongakukhetha | ||
Ukulungisa | Ifakwe odongeni noma imile | ||
Xhuma usayizi (mm) | φ150 | φ150 | φ200 |
Ukulawula Okukhaliphile: I-Tuya APP ngokuhlanganyela nesilawuli esihlakaniphile inikeza uchungechunge lwemisebenzi eklanyelwe izidingo ezihlukahlukene zephrojekthi.
Isibonisi sezinga lokushisa sivumela ukugadwa njalo kwamazinga okushisa angaphakathi nangaphandle.
Isici sokuqalisa kabusha ngokuzenzakalela samandla siqinisekisa ukuthi isistimu ye-ERV ilulama ngokuzenzakalelayo ekunqamukeni kukagesi.
Ukulawulwa kokugxilisa kwe-CO2 kugcina ikhwalithi yomoya ephezulu. Inzwa yokuswakama ilawula amazinga womswakamo wasendlini.
Izixhumi ze-RS485 zisiza ukulawula okumaphakathi nge-BMS. Ukulawula kwangaphandle kanye nokukhishwa kwesignali yokuvula/kwephutha kwenza abalawuli baphathe futhi balawule isifaki-moya kalula.
Isistimu ye-alamu yesihlungi ixwayisa abasebenzisi ukuthi bahlanze isihlungi ngesikhathi esifanele.